example_diagnostic_test.c File Reference
#include <stdbool.h>
#include <stdint.h>
#include <stdio.h>
#include <stdlib.h>
#include "acc_definitions_a121.h"
#include "acc_definitions_common.h"
#include "acc_hal_definitions_a121.h"
#include "acc_hal_integration_a121.h"
#include "acc_integration.h"
#include "acc_rss_a121.h"
#include "acc_version.h"

Go to the source code of this file.

Macros

#define SENSOR_ID   (1U)
 
#define SENSOR_TIMEOUT_MS   (1000U)
 

Functions

int acconeer_main (int argc, char *argv[])
 Assembly test example. More...
 

Macro Definition Documentation

◆ SENSOR_ID

#define SENSOR_ID   (1U)
Examples
example_diagnostic_test.c.

Definition at line 34 of file example_diagnostic_test.c.

◆ SENSOR_TIMEOUT_MS

#define SENSOR_TIMEOUT_MS   (1000U)
Examples
example_diagnostic_test.c.

Definition at line 36 of file example_diagnostic_test.c.

Function Documentation

◆ acconeer_main()

int acconeer_main ( int  argc,
char *  argv[] 
)

Assembly test example.

Touchless button application.

Tank level reference application.

Smart presence reference application.

Parking application.

Breathing example application.

Waste level application.

Vibration example.

Surface velocity example application.

Service subsweeps example.

Service multple configurations example.

Low power service example.

Service sensor calibration caching example.

Service example.

Processing subtract adaptive background example.

Processing static presence example.

Processing peak interpolation example.

Processing noncoherent mean example.

Processing coherent mean example.

Processing amplitude example.

hand motion application

Detector presence example with multiple configurations.

Low power detector presence example.

Detector presence example.

Detector distance example with iq data print.

Distance detector low power example.

Detector distance with calibration caching example.

Detector distance example.

Control helper example.

Cargo application.

Returns
Returns EXIT_SUCCESS if successful, otherwise EXIT_FAILURE

Test if measure on wake up is enable Do a measurement if the the detector is ready (configured and calibrated)

Test if measure on wake up is enable Do a measurement if the the detector is ready (configured and calibrated)

Detector filters and states are reset on prepare (reconfiguration) to avoid risk of false detections when switching back to a zone.

Detector filters and states are reset on prepare (reconfiguration) to avoid risk of false detections when switching back to a zone.

Examples
example_diagnostic_test.c.

Definition at line 40 of file example_diagnostic_test.c.